A novel Laccase Biosensor based on Laccase immobilized Graphene-Cellulose Microfiber Composite modified Screen-Printed Carbon Electrode for Sensitive Determination of Catechol

Новый лакказный биосенсор на основе модифицированного графеново-целлюлозным микроволоконным композитом трафаретно-печатного углеродного электрода с иммобилизованной лакказой для высокочувствительного определения катехола
Thomas C.‐K. Yang, Shen‐Ming Chen, Selvakumar Palanisamy, Tse-Wei Chen, Vijayalakshmi Velusamy, Yifan Pan, Sayee Kannan Ramaraj, Sonadevi Selvam
2017-01-24

amperometric detectioncatechol detectiongraphene-cellulose microfiber compositelaccase biosensorscreen-printed carbon electrode
Abstract In the present work, we demonstrate the fabrication of laccase biosensor to detect the catechol (CC) using laccase immobilized on graphene-cellulose microfibers (GR-CMF) composite modified screen printed carbon electrode (SPCE). The direct electrochemical behavior of laccase was investigated using laccase immobilized different modified SPCEs, such as GR/SPCE, CMF/SPCE and GR-CMF/SPCE. Compared with laccase immobilized GR and CMF modified SPCEs, a well-defined redox couple of CuI/CuIIfor laccase was observed at laccase immobilized GR-CMF composite modified SPCE. Cyclic voltammetry results show that the as-prepared biosensor has 7 folds higher catalytic activity with lower oxidation potential towards CC than SPCE modified with GR-CMF composite. Under optimized conditions, amperometrici-tmethod was used for the quantification of CC, and the amperometric response of the biosensor was linear over the concertation of CC ranging from 0.2 to 209.7 μM. The sensitivity, response time and the detection limit of the biosensor for CC is 0.932 μMμA−1cm−2, 2 s and 0.085 μM, respectively. The biosensor has high selectivity towards CC in the presence of potentially active biomolecules and phenolic compounds. The biosensor also accessed for the detection of CC in different water samples and shows good practicality with an appropriate repea.
1
A laccase biosensor was fabricated by immobilizing laccase on a graphene–cellulose microfiber composite-modified screen-printed carbon electrode.
2
Catechol detection was linear from 0.2 to 209.7 μM, with 0.932 μA μM⁻¹ cm⁻² sensitivity, 2 s response time, and 0.085 μM detection limit.
3
The biosensor exhibited sevenfold higher catalytic activity and a lower oxidation potential for catechol than the graphene–cellulose microfiber-modified electrode without laccase.
4
The biosensor showed high selectivity against potentially interfering biomolecules and phenolic compounds and performed well in different water samples.
5
The graphene–cellulose microfiber electrode enabled a well-defined Cu(I)/Cu(II) redox couple for immobilized laccase, unlike graphene- or cellulose-only electrodes.

Laccase immobilized on a graphene–cellulose microfiber composite-modified screen-printed carbon electrode for catechol detection

The electrochemical catalytic activity, sensitivity, selectivity, response time, and detection performance of the laccase biosensor for catechol

Publication Details
Publication Date
2017-01-24
Journal
Publisher
ISSN
Cited by
132
Access Type
Author Information
Authors
Thomas C.‐K. Yang
Shen‐Ming Chen
Selvakumar Palanisamy
Tse-Wei Chen
Vijayalakshmi Velusamy
Yifan Pan
Sayee Kannan Ramaraj
Sonadevi Selvam
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%