Utility of feline coronavirus antibody tests
Применимость тестов на антитела к коронавирусу кошек
2014-06-25
SCID: 54.1/gghex8cv
Discuss with AI
enzyme-linked immunosorbent assayfeline coronavirus antibody testsfeline infectious peritonitisindirect immunofluorescent antibody testrapid immunochromatographic tests
Figures from the paper
Abstract (AI)
Eight different tests for antibodies to feline coronavirus (FCoV) were evaluated for attributes that are important in situations in veterinary practice. We compared four indirect immunofluorescent antibody tests (IFAT), one enzyme-linked immunosorbent assay (ELISA) (FCoV Immunocomb; Biogal) and three rapid immunochromatographic (RIM) tests against a panel of samples designated by consensus as positive or negative. Specificity was 100% for all but the two IFATs based on transmissible gastroenteritis virus (TGEV), at 83.3% and 97.5%. The IFAT and ELISA tests were best for obtaining an antibody titre and for working in the presence of virus. The RIM tests were the best for obtaining a result quickly (10-15 mins); of these, the Speed F-Corona was the most sensitive, at 92.4%, followed by FASTest feline infectious peritonitis (FIP; 84.6%) and Anigen Rapid FCoV antibody test (64.1%). Sensitivity was 100% for the ELISA, one FCoV IFAT and one TGEV IFAT; and 98.2% for a second TGEV IFA and 96.1% for a second FCoV IFAT. All tests worked with effusions, even when only blood products were stipulated in the instruction manual. The ELISA and Anigen RIM tests were best for small quantities of sample. The most appropriate FCoV antibody test to use depends on the reason for testing: in excluding a diagnosis of FIP, sensitivity, specificity, small sample quantity, rapidity and ability to work in the presence of virus all matter. For FCoV screening, speed and sensitivity are important, and for FCoV elimination antibody titre is essential.
Key Findings
1
All tests worked with effusion samples, and the most appropriate assay depends on whether the goal is FIP exclusion, FCoV screening, or antibody-titre assessment for elimination programs.
2
Eight feline coronavirus antibody tests showed differing performance profiles across specificity, sensitivity, speed, sample volume, and virus compatibility.
3
IFAT and ELISA tests were best for antibody titration and testing in the presence of virus, while ELISA and Anigen RIM performed best with small sample volumes.
4
Rapid immunochromatographic tests produced results within 10–15 minutes, with Speed F-Corona being the most sensitive RIM test at 92.4%.
5
Sensitivity reached 100% for the ELISA, one FCoV IFAT, and one TGEV IFAT; other assays ranged from 96.1% to 98.2%, while RIM tests ranged from 64.1% to 92.4%.
6
Specificity was 100% for all tests except two TGEV-based IFATs, which showed specificities of 83.3% and 97.5%.
Research Object
Feline coronavirus antibody tests used in veterinary practice
Research Subject
Diagnostic performance and practical utility, including sensitivity, specificity, antibody-titre determination, speed, sample-volume requirements, and tolerance of virus presence