Numerical investigation of thermal contrast for interfacial debonding detection in concrete-filled steel tubular structures under hydration heat
Численное исследование теплового контраста для обнаружения межфазного отслоения в конструкциях из стальных труб, заполненных бетоном, при тепловыделении в процессе гидратации
2025-08-13
SCID: 54.1/kau7vven
Discuss with AI
CFST structuresfinite element methodhydration heatinterfacial debonding detectionthermal contrast
Figures from the paper
Abstract (AI)
Concrete-filled steel tubular (CFST) structures are extensively used for infrastructures, but the issue of debonding formation during construction remains prevalent. To address and mitigate this problem, this study investigates the temperature variations on the surface of the CFST structure during the heat of the hydration stage to facilitate timely debonding detection. The research employs the theory of heat conduction in CFST specimens, utilizing the finite element method to simulate the thermal conduction processes in CFST specimens under hydration conditions. Through experimental validation and finite element analysis, the impact of various factors—including ambient temperature, concrete casting temperature, steel plate thickness, debonding dimensions, debonding thickness, and concrete heating rate—on the surface temperature distribution of CFST specimens have been evaluated. Studies have shown that under varying ambient and initial temperatures (16 °C–51 °C), the surface ambient temperature difference ( θT ) exhibits a linear relationship with thermal contrast, with a slope of 0.037. The debonding size(20–140 mm) is linearly and positively correlated with the thermal contrast variation rate ( β ), with a slope of 0.00039. Debonding thickness(1–30 mm) and steel plate thickness(1–25 mm) show exponential relationships with β , which can be described using an empirical formula: y = a ⋅* exp (− x /b) + c . In addition, an exponential relationship model between the debonding-to-steel plate thickness ratio ( Dv / Ds ) and θT was established.
Key Findings
1
Across ambient and initial temperatures of 16–51 °C, thermal contrast varies linearly with surface ambient temperature difference, with a slope of 0.037.
2
An exponential model was established linking the debonding-to-steel plate thickness ratio to surface thermal contrast, supporting quantitative debonding assessment.
3
Debonding sizes of 20–140 mm show a positive linear relationship with the thermal contrast variation rate, with a slope of 0.00039.
4
Debonding thicknesses of 1–30 mm and steel plate thicknesses of 1–25 mm exhibit exponential relationships with thermal contrast variation rate, described by an empirical exponential formula.
5
Finite-element simulations, supported by experiments, investigate hydration-induced surface temperature variations for detecting debonding in concrete-filled steel tubular structures.
Research Object
concrete-filled steel tubular (CFST) structures during the hydration-heat stage
Research Subject
surface thermal contrast and temperature-distribution relationships for detecting interfacial debonding under varying environmental, geometric, and heating conditions