Cooling-excited infrared thermography for enhancing the detection of concrete filled steel tube interfacial debonding at concrete hydration
Инфракрасная термография с охлаждающим возбуждением для повышения эффективности обнаружения межфазного отслоения в стальных трубах, заполненных бетоном, в процессе гидратации бетона
2024-02-20
SCID: 54.1/veczmmr6
Discuss with AI
CFST interfacial debondingconcrete hydration heatcooling-excited infrared thermographythermal contrast enhancementwater-spray cooling
Figures from the paper
Abstract (AI)
Interfacial Debonding occurring in concrete-filled steel Tube (CFST) arch bridges during construction is a critical issue, which can reduce the CFST carrying capacity and thus degrade the operational lifespan of the bridge. Timely detection of this type of defect during bridge construction can be highly cost-effective but rare sensing technology was reported for detection at this stage. Infrared thermography has been recognized as a potential detection method but still faces the challenge of low thermal contrast developed from concrete hydration. This research investigates the feasibility of using hydration heat as an internal heat source and proposes water-spray cooling as an external excitation to improve infrared debonding detection. The experimental study is carried out to investigate the detectability enhancement before and after the cooling excitation in terms of different debonding sizes and thicknesses. An image enhancement method is then proposed for debonding visualization based on the temperature difference matrix. In addition, the numerical simulation is conducted to analyze the cooling effect regarding the excitation intensity variation. The findings reveal that the thermal contrast of debonding ranges from 0.1~0.35℃ before cooling excitation and is enhanced by 2~3 times thereafter. In addition, the developed maximum thermal contrast of debonding can be characterized through a linear relationship to the cooling excitation intensity based on numerical analysis. The proposed method shows significant feasibility for early detection of debonding in CFST during arch bridge construction, which enables a new potential for structural inspection.
Key Findings
1
A temperature-difference-matrix image enhancement method was developed to visualize interfacial debonding more effectively.
2
Before cooling, debonding thermal contrast ranges from 0.1 to 0.35℃, indicating limited detectability during hydration.
3
Concrete hydration heat can serve as an internal heat source for infrared thermographic detection of interfacial debonding in CFST structures.
4
Numerical analysis shows that maximum debonding thermal contrast varies linearly with cooling excitation intensity, supporting early CFST inspection during bridge construction.
5
Water-spray cooling provides external thermal excitation that enhances debonding thermal contrast by 2–3 times.
Research Object
concrete-filled steel tube (CFST) interfaces in arch bridges during concrete hydration and construction
Research Subject
enhancement and characterization of infrared-thermographic detection of interfacial debonding under hydration heat and water-spray cooling, including dependence on debonding size, thickness, and cooling intensity
Publication Details
Publication Date
2024-02-20
Journal
Publisher
ISSN
Cited by
27
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest
Cited by3
Experimental study on infrared detection of debonding in concrete-filled steel tubular structure under acceleratory period of hydration heat action2024
Quantitative infrared detection methods for debonding in concrete-filled steel tubes during the hydration heat phase2025
Numerical investigation of thermal contrast for interfacial debonding detection in concrete-filled steel tubular structures under hydration heat2025