The prevalence of orthopedic metal implants is continuously rising in the aging society. Particularly the number of joint replacements is increasing. Although satisfying long-term results are encountered, patients may suffer from complaints or complications during follow-up, and often undergo magnetic resonance imaging (MRI). Yet metal implants cause severe artifacts on MRI, resulting in signal-loss, signal-pileup, geometric distortion, and failure of fat suppression. In order to allow for adequate treatment decisions, metal artifact reduction sequences (MARS) are essential for proper radiological evaluation of postoperative findings in these patients. During recent years, developments of musculoskeletal imaging have addressed this particular technical challenge of postoperative MRI around metal. Besides implant material composition, configuration and location, selection of appropriate MRI hardware, sequences, and parameters influence artifact genesis and reduction. Application of dedicated metal artifact reduction techniques including high bandwidth optimization, view angle tilting (VAT), and the multispectral imaging techniques multiacquisition variable-resonance image combination (MAVRIC) and slice-encoding for metal artifact correction (SEMAC) may significantly reduce metal-induced artifacts, although at the expense of signal-to-noise ratio and/or acquisition time. Adding advanced image acquisition techniques such as parallel imaging, partial Fourier transformation, and advanced reconstruction techniques such as compressed sensing further improves MARS imaging in a clinically feasible scan time. This review focuses on current clinically applicable MARS techniques. Understanding of the main principles and techniques including their limitations allows a considerate application of these techniques in clinical practice. Essential orthopedic metal implants and postoperative MR findings around metal are presented and highlighted with clinical examples. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2017;46:972-991.
1
Artifact severity and reduction depend on implant composition, configuration, location, MRI hardware, sequence selection, and imaging parameters.
2
High-bandwidth optimization, view angle tilting, MAVRIC, and SEMAC can substantially reduce metal artifacts, but may decrease signal-to-noise ratio or increase acquisition time.
3
Metal artifact reduction sequences are essential for reliable postoperative MRI evaluation and appropriate treatment decisions in patients with orthopedic implants.
4
Orthopedic metal implants produce severe MRI artifacts, including signal loss, signal pileup, geometric distortion, and failed fat suppression.
5
Parallel imaging, partial Fourier acquisition, and compressed sensing improve the clinical feasibility of metal artifact reduction imaging by shortening scan times.

Magnetic resonance imaging (MRI) performed in the presence of metallic implants or around metal

clinically applicable metal artifact reduction techniques and their limitations for evaluating postoperative findings around implants

Publication Details
Publication Date
2017-03-25
Journal
Publisher
ISSN
Access Type
Author Information
Authors
Reto Sutter
Pia M. Jungmann
Christoph A. Agten
Christian W. A. Pfirrmann
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat
Make a presentation
100%