Raster Orientation Effects on the Adhesion of iCVD-Deposited PSA Thin Films on FDM-Printed PLA
Влияние ориентации растра на адгезию тонких плёнок PSA, нанесённых методом iCVD, на PLA, напечатанном методом FDM
2026-01-30
SCID: 54.1/m33tj5t5
Discuss with AI
FDM-printed PLAadhesion strengthinitiated chemical vapor depositionpressure-sensitive adhesive thin filmsraster orientation
Figures from the paper
Abstract (AI)
The adhesion performance of pressure-sensitive adhesive (PSA) thin films on additively manufactured polymers is strongly governed by surface anisotropy induced during printing. In this study, PSA thin films based on 2-ethylhexyl acrylate (EHA) and acrylic acid (AA) were deposited by initiated chemical vapor deposition (iCVD) onto fused deposition modeling (FDM) printed PLA substrates with different raster orientations (0°, 30°, 60°, and 90°). The deposited films exhibited high optical transparency on glass, and thicknesses consistent with the targeted deposition. Adhesion performance was evaluated using tensile and three-point bending tests, revealing a strong dependence on raster orientation. The 0° raster orientation yielded the highest shear adhesion strengths, reaching 12.03 N/cm2 under tensile loading and 4.59 N/cm2 under bending, along with the largest failure displacements. In contrast, specimens printed at 90° exhibited an approximately 47% reduction in tensile shear adhesion strength and limited deformation prior to failure. SEM analysis showed that raster alignment parallel to the loading direction promoted extensive adhesive deformation and PSA fibrillation, whereas higher raster angles resulted in predominantly interfacial debonding. These results demonstrate that raster orientation is a critical design parameter for tuning PSA adhesion on FDM-printed PLA substrates without modifying adhesive chemistry.
Key Findings
1
A 0° raster orientation produced the highest shear adhesion strengths: 12.03 N/cm² in tensile loading and 4.59 N/cm² in bending.
2
Compared with 0°, 90° raster specimens exhibited approximately 47% lower tensile shear adhesion strength and limited deformation before failure.
3
Parallel raster alignment promoted extensive adhesive deformation and PSA fibrillation, whereas higher raster angles primarily caused interfacial debonding.
4
Raster orientation can tune PSA adhesion on FDM-printed PLA without changing the adhesive chemistry.
5
iCVD-deposited EHA/AA PSA thin films showed adhesion strongly dependent on the raster orientation of FDM-printed PLA substrates.
Research Object
iCVD-deposited pressure-sensitive adhesive (PSA) thin films on FDM-printed PLA substrates with different raster orientations
Research Subject
The dependence of adhesion strength, deformation, failure displacement, and debonding/fibrillation behavior on raster orientation
Publication Details
Publication Date
2026-01-30
Journal
Publisher
ISSN
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest