Samples with high virus load cause a trend toward lower signal in feline coronavirus antibody tests
Образцы с высокой вирусной нагрузкой демонстрируют тенденцию к снижению сигнала в тестах на антитела к коронавирусу кошек
2012-12-06
SCID: 54.1/n2j75h9n
Discuss with AI
enzyme-linked immunosorbent assayfeline coronavirusfeline infectious peritonitisindirect immunofluorescencereal-time RT-PCR
Figures from the paper
Abstract (AI)
Measurement of feline coronavirus (FCoV) antibody titres is utilised mainly for diagnosing feline infectious peritonitis (FIP) and for quarantine purposes. However, occasional samples show a falsely low or negative FCoV antibody test. We tested the hypothesis that such results are due to virus in the sample binding antibody and rendering it unavailable to antigen in the test. Thirteen effusions, one plasma and three undefined samples from cats with FIP, which gave unexpectedly low FCoV antibody titres, were examined by real-time reverse transcriptase polymerase chain reaction (RT-PCR). Increasing amounts of virus correlated with lower signals in indirect immunoflourescent, enzyme-linked immunosorbent asssay and rapid immunomigration antibody tests. However, five samples were negative by RT-PCR, so the presence of virus alone may not explain all cases of false-negative FCoV antibody tests, although it is a possible explanation in 71% of discordant samples. We conclude that falsely low or negative FCoV antibody tests can occur in samples rich in virus.
Key Findings
1
Among 17 samples from cats with feline infectious peritonitis and unexpectedly low antibody titres, increasing viral RNA amounts correlated with decreasing test signals.
2
FCoV-rich samples can produce falsely low or negative antibody-test results, limiting interpretation for FIP diagnosis and quarantine testing.
3
Five samples were negative by RT-PCR, indicating that viral presence alone does not explain all unexpectedly low or negative FCoV antibody tests.
4
Samples with high feline coronavirus (FCoV) loads showed a trend toward lower antibody-test signals across immunofluorescence, ELISA, and rapid immunomigration assays.
5
Virus-associated interference may explain false-negative or falsely low FCoV antibody results in 71% of discordant samples.
Research Object
Feline coronavirus–rich samples from cats with feline infectious peritonitis, including effusions, plasma, and undefined samples
Research Subject
The effect of viral load on FCoV antibody test signals and the occurrence of falsely low or negative antibody titres
Publication Details
Publication Date
2012-12-06
Journal
Publisher
ISSN
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest
Cited by4
Feline Infectious Peritonitis: European Advisory Board on Cat Diseases Guidelines2023
An updated review of feline coronavirus: mind the two biotypes2023
Diagnosis of feline infectious peritonitis: Update on evidence supporting available tests2018
An update on feline infectious peritonitis: Diagnostics and therapeutics2014