An Insulin Infusion Advisory System Based on Autotuning Nonlinear Model-Predictive Control

Система рекомендаций по инфузии инсулина на основе самонастраивающегося нелинейного управления с прогнозированием модели
Konstantina S. Nikita, Konstantia Zarkogianni, Stavroula Georgia Mougiakakou, Andriani Vazeou, Aikaterini Prountzou
2011-05-27

continuous glucose monitoringfuzzy logic autotuninginsulin infusion advisory systemnonlinear model-predictive controltype 1 diabetes mellitus
This paper aims at the development and evaluation of a personalized insulin infusion advisory system (IIAS), able to provide real-time estimations of the appropriate insulin infusion rate for type 1 diabetes mellitus (T1DM) patients using continuous glucose monitors and insulin pumps. The system is based on a nonlinear model-predictive controller (NMPC) that uses a personalized glucose-insulin metabolism model, consisting of two compartmental models and a recurrent neural network. The model takes as input patient's information regarding meal intake, glucose measurements, and insulin infusion rates, and provides glucose predictions. The predictions are fed to the NMPC, in order for the latter to estimate the optimum insulin infusion rates. An algorithm based on fuzzy logic has been developed for the on-line adaptation of the NMPC control parameters. The IIAS has been in silico evaluated using an appropriate simulation environment (UVa T1DM simulator). The IIAS was able to handle various meal profiles, fasting conditions, interpatient variability, intraday variation in physiological parameters, and errors in meal amount estimations.
1
An online fuzzy-logic algorithm adapts the NMPC control parameters to account for changing patient conditions.
2
Developed a personalized insulin infusion advisory system combining continuous glucose monitoring, insulin pumps, and nonlinear model-predictive control.
3
In silico evaluation with the UVA T1DM simulator showed robustness across varied meals, fasting, interpatient and intraday physiological variability, and meal-estimation errors.
4
The system uses a personalized glucose-insulin model comprising two compartmental models and a recurrent neural network to predict future glucose levels.

personalized insulin infusion advisory system for type 1 diabetes mellitus patients

real-time estimation and adaptive control of appropriate insulin infusion rates under meal, fasting, patient-variability, intraday-variation, and meal-estimation-error conditions

Publication Details
Publication Date
2011-05-27
Journal
Publisher
ISSN
Cited by
80
Access Type
Author Information
Authors
Konstantina S. Nikita
Konstantia Zarkogianni
Stavroula Georgia Mougiakakou
Andriani Vazeou
Aikaterini Prountzou
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%