Methane emission detection, localization, and quantification using continuous point-sensors on oil and gas facilities
Обнаружение, локализация и количественная оценка выбросов метана с использованием непрерывных точечных датчиков на объектах нефтегазовой отрасли
2022-12-26
SCID: 54.1/nm6t6yrx
Discuss with AI
continuous emissions monitoringemission rate quantificationemission source localizationgradient-based spike detectionmethane emissions
Figures from the paper
Abstract (AI)
We propose a generic, modular framework for emission event detection, localization, and quantification on oil and gas facilities that uses concentration data collected by point-in-space continuous emissions monitoring systems (CEMS). The framework uses a gradient-based spike detection algorithm to estimate emission start and end times (event detection) and pattern matches simulated and observed concentrations to estimate emission source location (localization) and rate (quantification). We test the framework on a month of single-source controlled releases ranging from 0.50 to 8.25 hours in duration and 0.18 to 6.39 kg/hr in size conducted at the Methane Emissions Technology Evaluation Center in Fort Collins, Colorado. All controlled releases are identified and 82% are localized correctly. For emissions <1 kg/hr, the framework underestimates by 37.2% on average, with 90% of rate estimates within a factor of [-4.6, 2.8] or a percent difference of [-78.1%, 178.6%]; for emissions > 1 kg/hr, the framework overestimates by 1.5% on average, with 90% of rate estimates within a factor of [-2.0, 1.8] or a percent difference of [-49.6%, 77.4%] from the true rates. Potential uses for the proposed framework include near real-time alerting for rapid emissions mitigation and emission quantification for data-driven inventory estimation on production-like facilities.
Key Findings
1
A modular framework uses continuous point-sensor concentration data for methane event detection, source localization, and emission-rate quantification.
2
For emissions above 1 kg/hr, rates were overestimated by 1.5% on average; 90% of estimates fell within factors of [-2.0, 1.8].
3
For emissions below 1 kg/hr, rates were underestimated by 37.2% on average; 90% of estimates fell within factors of [-4.6, 2.8].
4
Gradient-based spike detection estimates emission start and end times, while matching simulated and observed concentration patterns infers source location and rate.
5
The framework could support near-real-time mitigation alerts and data-driven emissions inventory estimation on production-like facilities.
6
The framework detected all single-source controlled releases spanning 0.18–6.39 kg/hr and 0.50–8.25 hours, and localized 82% correctly.
Research Object
Methane emission events from oil and gas facilities
Research Subject
Detection, source localization, and rate quantification of methane emissions using continuous point-in-space concentration measurements