Laccase Biosensor Based on Electrospun Copper/Carbon Composite Nanofibers for Catechol Detection
Лакказный биосенсор на основе электроформованных медь-углеродных композитных нановолокон для определения катехола
2014-02-20
SCID: 54.1/p28km326
Discuss with AI
amperometric biosensorcarbon nanofiberscatechol detectionelectrospun Cu/CNFslaccase biosensor
Figures from the paper
Abstract (AI)
The study compared the biosensing properties of laccase biosensors based on carbon nanofibers (CNFs) and copper/carbon composite nanofibers (Cu/CNFs). The two kinds of nanofibers were prepared by electrospinning and carbonization under the same conditions. Scanning electron microscopy (SEM), X-ray diffraction (XRD) and Raman spectroscopy were employed to investigate the morphologies and structures of CNFs and Cu/CNFs. The amperometric results indicated that the Cu/CNFs/laccase(Lac)/Nafion/glass carbon electrode (GCE) possessed reliable analytical performance for the detection of catechol. The sensitivity of the Cu/CNFs/Lac/Nafion/GCE reached 33.1 μA/mM, larger than that of CNFs/Lac/Nafion/GCE. Meanwhile, Cu/CNFs/Lac/Nafion/GCE had a wider linear range from 9.95 × 10(-6) to 9.76 × 10(-3) M and a lower detection limit of 1.18 μM than CNFs/Lac/Nafion/GCE. Moreover, it exhibited a good repeatability, reproducibility, selectivity and long-term stability, revealing that electrospun Cu/CNFs have great potential in biosensing.
Key Findings
1
Electrospun carbon nanofibers and copper/carbon composite nanofibers were fabricated by identical electrospinning and carbonization conditions for comparative biosensor evaluation.
2
The Cu/CNFs-based biosensor provided a linear catechol detection range of 9.95 × 10⁻⁶ to 9.76 × 10⁻³ M and a detection limit of 1.18 μM.
3
The Cu/CNFs/laccase/Nafion/glass carbon electrode achieved a catechol sensitivity of 33.1 μA/mM, exceeding that of the corresponding carbon-nanofiber biosensor.
4
The copper/carbon composite biosensor demonstrated good repeatability, reproducibility, selectivity, and long-term stability.
5
The results indicate that electrospun copper/carbon composite nanofibers are promising electrode materials for laccase-based catechol biosensing.
Research Object
laccase biosensors based on electrospun copper/carbon composite nanofibers (Cu/CNFs) and carbon nanofibers (CNFs) for catechol detection
Research Subject
comparative analytical performance, including sensitivity, linear range, detection limit, repeatability, reproducibility, selectivity, and long-term stability, for amperometric catechol detection
Publication Details
Publication Date
2014-02-20
Journal
Publisher
ISSN
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest