Quantitative estimation of insulin sensitivity.
Количественная оценка чувствительности к инсулину
1979-06-01
SCID: 54.1/tjqnqsj2
Discuss with AI
conscious dogsglucose disappearanceglucose injectioninsulin sensitivity indexnonlinear mathematical model
Figures from the paper
Abstract (AI)
We have evaluated the feasibility of using a mathematical model of glucose disappearance to estimate insulin sensitivity. Glucose was injected into conscious dogs at 100, 200, or 300 mg/kg. The measured time course of insulin was regarded as the "input," and the falling glucose concentration as the "output" of the physiological system storing and using glucose. Seven mathematical models of glucose uptake were compared to identify the representation most capable of simulating glucose disappearance. One specific nonlinear model was superior in that it 1) predicted the time course of glucose after glucose injection, 2) had four parameters that could be precisely estimated, and 3) described individual experiments with similar parameter values. Insulin sensitivity index (SI), defined as the dependence of fractional glucose disappearance on plasma insulin, was the ratio of two parameters of the chosen model and could be estimated with good reproducibility from the 300 mg/kg injection experiments (SI = 7.00 X 10(-4) +/- 24% (coefficient of variation) min-1/(microU/ml) (n = 8)). Thus, from a single glucose injection it is possible to obtain a quantitative index of insulin sensitivity that may have clinical applicability.
Key Findings
1
A mathematical model of glucose disappearance was evaluated for estimating insulin sensitivity from a single glucose injection.
2
Insulin sensitivity was defined as the dependence of fractional glucose disappearance on plasma insulin and calculated as the ratio of two model parameters.
3
Seven glucose-uptake models were compared; one nonlinear model best simulated post-injection glucose disappearance.
4
The selected model accurately predicted glucose time courses, had four precisely estimable parameters, and produced similar parameter values across individual experiments.
5
Using 300 mg/kg glucose injections in conscious dogs, insulin sensitivity was reproducibly estimated as 7.00 × 10^-4 ± 24% min^-1/(µU/ml) (n = 8), suggesting clinical applicability.
Research Object
Glucose disappearance and insulin-mediated glucose uptake in conscious dogs after intravenous glucose injection
Research Subject
Quantitative estimation and reproducibility of insulin sensitivity from the dependence of fractional glucose disappearance on plasma insulin using a nonlinear mathematical model
Publication Details
Publication Date
1979-06-01
Journal
Publisher
ISSN
Cited by
1867
Access Type
Author Information
Download PDF
Subscribe to digest
References available in scid.ai1
Cited by6
A physiological model of glucose-insulin interaction in type 1 diabetes mellitus1992
A Closed-Loop Artificial Pancreas Using Model Predictive Control and a Sliding Meal Size Estimator2009
Hypoglycemia Prevention via Pump Attenuation and Red-Yellow-Green “Traffic” Lights Using Continuous Glucose Monitoring and Insulin Pump Data2010
The Artificial Pancreas and Meal Control: An Overview of Postprandial Glucose Regulation in Type 1 Diabetes2018
A Novel Insulin/Glucose Model after a Mixed-Meal Test in Patients with Type 1 Diabetes on Insulin Pump Therapy2016
Safe Glucose Regulation in Artificial Pancreas Systems via Robust Control Barrier Functions2025