The objective of this article is to present a comprehensive strategy for a closed-loop artificial pancreas. A meal detection and meal size estimation algorithm is developed for situations in which the subject forgets to provide a meal insulin bolus. A pharmacodynamic model of insulin action is used to provide insulin-on-board constraints to explicitly include the future effect of past and currently delivered insulin boluses. In addition, a supervisory pump shut-off feature is presented to avoid hypoglycemia. All of these components are used in conjunction with a feedback control algorithm using model predictive control (MPC). A model for MPC is developed based on a study of 20 subjects and is tested in a hypothetical clinical trial of 100 adolescent and 100 adult subjects using a Food and Drug Administration-approved diabetic subject simulator. In addition, a performance comparison of previously and newly proposed meal size estimation algorithms using 200 in silico subjects is presented. Using the new meal size estimation algorithm, the integrated artificial pancreas system yielded a daily mean glucose of 138 and 132 mg/dl for adolescents and adults, respectively, which is a substantial improvement over the MPC-only case, which yielded 159 and 145 mg/dl.
1
A comprehensive closed-loop artificial pancreas integrates meal detection, meal-size estimation, insulin-on-board constraints, supervisory pump shut-off, and MPC feedback control.
2
A pharmacodynamic insulin-action model explicitly constrains insulin-on-board, accounting for future effects of previously and currently delivered insulin.
3
In simulator trials, the integrated system achieved daily mean glucose levels of 138 mg/dl in adolescents and 132 mg/dl in adults.
4
The integrated system substantially outperformed MPC-only control, which produced mean glucose levels of 159 mg/dl in adolescents and 145 mg/dl in adults.
5
The meal detection and size estimation algorithm addresses missed meal boluses, enabling the system to compensate when subjects fail to announce meals.

closed-loop artificial pancreas system for insulin-dependent diabetes management

glucose-control performance and hypoglycemia prevention with meal detection and size estimation, insulin-on-board constraints, and MPC-based insulin delivery

Publication Details
Publication Date
2009-09-01
Journal
Journal of Diabetes Science and Technology
Publisher
SAGE Publishing
ISSN
1932-2968
Cited by
165
Access Type
Author Information
Authors
Hyunjin Lee
Bruce A. Buckingham
Darrell M. Wilson
B. Wayne Bequette
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%