An Optical Biosensor based on Immobilization of Laccase and MBTH in Stacked Films for the Detection of Catechol.

Оптический биосенсор на основе иммобилизации лакказы и MBTH в многослойных пленках для определения катехола
Lee Yook Heng, Jaafar Abdullah, Musa Ahmad, Nadarajah Karuppiah, Hamidah Sidek
2007-10-11

3-methyl-2-benzothiazolinone hydrazone (MBTH)catechol detectionlaccase immobilizationnafion/sol-gel silicate filmoptical biosensor
The fabrication of an optical biosensor by using stacked films where 3-methyl-2-benzothiazolinone hydrazone (MBTH) was immobilized in a hybrid nafion/sol-gelsilicate film and laccase in a chitosan film for the detection of phenolic compounds wasdescribed. Quinone and/or phenoxy radical product from the enzymatic oxidation ofphenolic compounds was allowed to couple with MBTH to form a colored azo-dye productfor spectrophometric detection. The biosensor demonstrated a linear response to catecholconcentration range of 0.5-8.0 mM with detection limit of 0.33 mM and response time of10 min. The reproducibility of the fabricated biosensor was good with RSD value of 5.3 %(n = 8) and stable for at least 2 months. The use of the hybrid materials of nafion/sol-gelsilicate to immobilize laccase has altered the selectivity of the enzyme to various phenoliccompounds such as catechol, guaicol, o-cresol and m-cresol when compared to the non-immobilized enzyme. When immobilized in this hybrid film, the biosensor response onlyto catechol and not other phenolic compounds investigated. Immobilization in this hybridmaterial has enable the biosensor to be more selective to catechol compared with the non-immobilized enzyme. This shows that by a careful selection of different immobilizationmatrices, the selectivity of an enzyme can be modified to yield a biosensor with goodselectivity towards certain targeted analytes.
1
A stacked-film optical biosensor immobilized MBTH in hybrid Nafion/sol-gel silicate and laccase in chitosan for phenolic-compound detection.
2
Enzymatic oxidation products coupled with MBTH to form a colored azo dye, enabling spectrophotometric catechol measurement.
3
Hybrid-film immobilization modified laccase selectivity, producing a response to catechol but not guaiacol, o-cresol, or m-cresol.
4
The biosensor demonstrated good reproducibility (5.3% RSD, n = 8) and remained stable for at least two months.
5
The biosensor showed a linear catechol response from 0.5–8.0 mM, a 0.33 mM detection limit, and a 10-minute response time.

A stacked-film optical biosensor with laccase and MBTH immobilized in hybrid nafion/sol-gelsilicate and chitosan films

Selective spectrophotometric detection of catechol, including the biosensor’s analytical response, selectivity, detection limit, reproducibility, and stability

Publication Details
Publication Date
2007-10-11
Journal
Publisher
ISSN
Cited by
86
Access Type
Author Information
Authors
Lee Yook Heng
Jaafar Abdullah
Musa Ahmad
Nadarajah Karuppiah
Hamidah Sidek
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%