A Framework for Optimizing Continuous Methane Monitoring System Configuration for Minimal Blind Time: Application and Insights from over 100 Operational Oil and Gas Facilities

Методика оптимизации конфигурации системы непрерывного мониторинга метана для минимизации времени слепого обнаружения: применение и результаты анализа более чем 100 действующих нефтегазовых объектов
Noah Metzger, Ali Lashgari, Umair Esmail, David Ball, Nathan Eichenlaub
2025-07-14

blind timecontinuous methane monitoringfixed-point sensorsoil and gas facilitiessensor network optimization
Continuous monitoring systems (CMS) that utilize fixed-point sensors provide high temporal resolution point-in-space measurements of ambient methane concentration. This study introduces a modular framework for optimizing CMS configurations, encompassing sensor density (number of sensors) and near-optimal placement. By introducing a metric called ‘blind time’, this study attempts to capture periods where the network fails to make detections that could satisfy the regulatory requirement of quantifying emissions every 12 h. This framework is then applied to 124 operational oil and gas production facilities with a wide variety of site characteristics and meteorological conditions. This study determines a representative blind time for near-optimum CMS configurations for operational facilities and then investigates the impact of different sensor network densities on the performance of the CMS. The results demonstrate that 3-sensor networks, when placed in near-optimum arrangements, can achieve blind time of less than 10% and a mean time to detection of approximately 82 min.
1
Near-optimal three-sensor networks achieved less than 10% blind time and an approximately 82-minute mean time to detection.
2
The analysis characterizes representative blind times and evaluates how sensor network density affects continuous monitoring performance.
3
The framework was applied to 124 operational oil and gas production facilities spanning diverse site characteristics and meteorological conditions.
4
The proposed “blind time” metric measures periods when a sensor network fails to detect emissions sufficiently to meet the requirement for quantification every 12 hours.
5
The study introduces a modular framework for optimizing continuous methane monitoring configurations, including sensor density and near-optimal placement.

Continuous methane monitoring systems using fixed-point sensors at operational oil and gas production facilities

Optimization of sensor-network density and placement to minimize blind time and improve methane-emission detection performance

Publication Details
Publication Date
2025-07-14
Journal
Publisher
ISSN
Access Type
Author Information
Authors
Noah Metzger
Ali Lashgari
Umair Esmail
David Ball
Nathan Eichenlaub
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%