Comparing Continuous Methane Monitoring Technologies for High-Volume Emissions: A Single-Blind Controlled Release Study
Сравнение технологий непрерывного мониторинга метана при крупных выбросах: исследование с контролируемыми выбросами и одиночным слепым контролем
2024-06-04
SCID: 54.1/tr9gz9c5
Discuss with AI
continuous methane monitoringcontrolled release testingfalse positive ratehigh-volume methane emissionsoil and gas operations
Figures from the paper
Abstract (AI)
High Resolution Image Download MS PowerPoint Slide Methane emissions from oil and gas operations are a primary concern for climate change mitigation. While traditional methane detection relies on periodic surveys that yield episodic data, continuous monitoring solutions promise to offer consistent insights and a richer understanding of emission inventories. Despite this promise, the detection and quantification abilities of continuous monitoring solutions remain unclear. To address this uncertainty, our study comprehensively assessed 8 commercial continuous monitoring solutions using controlled release tests to simulate high-volume venting (e.g., uncontrolled tanks, pneumatics, and unlit flares), which accounts for a significant fraction of total emissions from oil and gas systems. The performance of each team varied: when comparing reported results on a second-by-second basis, all teams reported false positive rates below 10%. For true positive rates, 4 out of 8 systems exceed 80%. In the field test where continuous monitoring solutions identified and reported an emission event, all systems’ reliability of identification surpassed 70%. When systems reported that there was no emission event, the reliability of nonemission identification varied from 29.4% to 96.2%. Among 5 systems tested for quantifying the daily average emission rate released by the Stanford team, all were underestimated by an average of 74.38% emissions. This indicates that their application in emissions reporting or regulation may be premature. The variability in monitor performance underscores the importance of understanding systems’ strengths and limitations before their broader adoption in methane mitigation approaches or regulatory frameworks.
Key Findings
1
All systems reported second-by-second false-positive rates below 10%, while only four of eight achieved true-positive rates exceeding 80%.
2
Five systems underestimated daily average emission rates by an average of 74.38%, suggesting regulatory or reporting use may be premature.
3
Reliability of identifying nonemission events varied substantially, ranging from 29.4% to 96.2% across systems.
4
The study evaluated eight commercial continuous methane-monitoring systems using controlled releases simulating high-volume oil and gas emissions.
5
When systems identified an emission event, identification reliability exceeded 70% for every tested system.
Research Object
Commercial continuous methane monitoring solutions applied to high-volume methane releases from oil and gas operations
Research Subject
Detection, identification reliability, false-positive and true-positive rates, and emission-rate quantification accuracy of continuous methane monitoring solutions
Publication Details
Publication Date
2024-06-04
Journal
Publisher
ISSN
Cited by
39
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest
References available in scid.ai3
A review of close-range and screening technologies for mitigating fugitive methane emissions in upstream oil and gas2019
Natural Gas Fugitive Leak Detection Using an Unmanned Aerial Vehicle: Localization and Quantification of Emission Rate2018
Point Sensor Networks Struggle to Detect and Quantify Short Controlled Releases at Oil and Gas Sites2024
Cited by7
Assessing the performance of emerging and existing continuous monitoring solutions under a single-blind controlled testing protocol2025
A Review of Source-Term Estimation for Continuous Methane Monitoring: From Data Acquisition to Modeling and Estimation2026
Validation Testing of Continuous Laser Methane Monitoring at Operational Oil and Gas Production Facilities2025
A Performance Evaluation Framework for Continuous Methane Monitoring: Effects of Event Association and Metric Choice2026
Access to Monitoring Data Reduces Methane Emissions at Operational Oil and Gas Facilities2026
A Framework for Optimizing Continuous Methane Monitoring System Configuration for Minimal Blind Time: Application and Insights from over 100 Operational Oil and Gas Facilities2025
Estimating Methane Emission Durations Using Continuous Monitoring Systems2024