Estimating Methane Emission Durations Using Continuous Monitoring Systems
Оценка продолжительности выбросов метана с использованием систем непрерывного мониторинга
2024-10-28
SCID: 54.1/czuzypvf
Discuss with AI
Probabilistic Duration Modelcontinuous monitoring systemscontrolled release evaluationmethane emission durationnondetect times
Figures from the paper
Abstract (AI)
High Resolution Image Download MS PowerPoint Slide We propose a method for estimating methane emission durations on oil and gas sites, referred to as the Probabilistic Duration Model (PDM), that uses concentration data from continuous monitoring systems (CMS). The PDM probabilistically addresses a key limitation of CMS: nondetect times, or the times when wind blows emitted methane away from the CMS sensors (resulting in no detections). Output from the PDM can be used to bound the duration of emissions detected by survey-based technologies, such as plane or satellites, that have limited ability to characterize durations due to the typically low temporal frequency (e.g., quarterly) at which they observe a given source. Linear regression indicates that the PDM has a bias of −4.9% (R 2 = 0.80) when evaluated on blinded controlled releases at the Methane Emissions Technology Evaluation Center (METEC), with 86.8% of estimates within a factor of 2× error from the true duration. We apply the PDM to a typical production site in the Appalachian Basin and use it to bound the duration of survey-based measurements. We find that failing to account for CMS nondetect times results in underestimated emission durations of up to a factor of 65× (6400%) on this site.
Key Findings
1
Ignoring CMS nondetect times underestimated emission durations by up to 65× (6400%) at a typical Appalachian Basin production site.
2
In blinded controlled releases at METEC, the PDM showed −4.9% bias, R² = 0.80, and 86.8% of estimates within 2× of true duration.
3
PDM outputs can bound emission durations measured by low-frequency survey technologies, including aircraft and satellites.
4
The PDM probabilistically accounts for CMS nondetect periods caused when wind transports emitted methane away from sensors.
5
The Probabilistic Duration Model (PDM) estimates methane emission durations from concentration data collected by continuous monitoring systems.
Research Object
Methane emissions on oil and gas production sites monitored by continuous monitoring systems
Research Subject
Emission-duration estimation, including the effects of sensor nondetect times and the resulting uncertainty or bias
Publication Details
Publication Date
2024-10-28
Journal
Publisher
ISSN
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest
References available in scid.ai3
Comparing Continuous Methane Monitoring Technologies for High-Volume Emissions: A Single-Blind Controlled Release Study2024
Assessing the Progress of the Performance of Continuous Monitoring Solutions under a Single-Blind Controlled Testing Protocol2024
Assessing Detection Efficiencies for Continuous Methane Emission Monitoring Systems at Oil and Gas Production Sites2023