Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association

Измерение артериального давления у человека: научное заявление Американской кардиологической ассоциации
Daichi Shimbo, Joseph E. Schwartz, Jackson T. Wright, Jeanne B. Charleston, Raymond R. Townsend, Paul Muntner, Martin G. Myers, Robert M. Carey, William B. White, Trudy R. Gaillard, Sanjay Misra, Gbenga G Ogedegbe, Elaine M. Urbina, Anthony J. Viera
2019-03-04

ambulatory blood pressure monitoringblood pressure measurementhome blood pressure monitoringmasked hypertensionwhite-coat hypertension
The accurate measurement of blood pressure (BP) is essential for the diagnosis and management of hypertension. This article provides an updated American Heart Association scientific statement on BP measurement in humans. In the office setting, many oscillometric devices have been validated that allow accurate BP measurement while reducing human errors associated with the auscultatory approach. Fully automated oscillometric devices capable of taking multiple readings even without an observer being present may provide a more accurate measurement of BP than auscultation. Studies have shown substantial differences in BP when measured outside versus in the office setting. Ambulatory BP monitoring is considered the reference standard for out-of-office BP assessment, with home BP monitoring being an alternative when ambulatory BP monitoring is not available or tolerated. Compared with their counterparts with sustained normotension (ie, nonhypertensive BP levels in and outside the office setting), it is unclear whether adults with white-coat hypertension (ie, hypertensive BP levels in the office but not outside the office) have increased cardiovascular disease risk, whereas those with masked hypertension (ie, hypertensive BP levels outside the office but not in the office) are at substantially increased risk. In addition, high nighttime BP on ambulatory BP monitoring is associated with increased cardiovascular disease risk. Both oscillometric and auscultatory methods are considered acceptable for measuring BP in children and adolescents. Regardless of the method used to measure BP, initial and ongoing training of technicians and healthcare providers and the use of validated and calibrated devices are critical for obtaining accurate BP measurements.
1
Ambulatory blood-pressure monitoring is the reference standard for out-of-office assessment, while home monitoring is an alternative when ambulatory monitoring is unavailable or intolerable.
2
Elevated nighttime blood pressure on ambulatory monitoring is associated with increased cardiovascular disease risk; validated devices and ongoing staff training are essential for accurate measurement.
3
Fully automated oscillometric devices that obtain multiple readings without an observer may measure blood pressure more accurately than auscultation.
4
Masked hypertension is associated with substantially increased cardiovascular disease risk, whereas the risk associated with white-coat hypertension remains unclear.
5
Validated oscillometric devices can improve office blood-pressure accuracy by reducing human errors associated with auscultatory measurement.

Blood pressure measurement in humans across office and out-of-office settings

Accuracy, validity, and cardiovascular-risk relevance of blood pressure measurements, including white-coat and masked hypertension and nighttime BP

Publication Details
Publication Date
2019-03-04
Journal
Publisher
ISSN
Cited by
1507
Access Type
Author Information
Authors
Daichi Shimbo
Joseph E. Schwartz
Jackson T. Wright
Jeanne B. Charleston
Raymond R. Townsend
Paul Muntner
Martin G. Myers
Robert M. Carey
William B. White
Trudy R. Gaillard
Sanjay Misra
Gbenga G Ogedegbe
Elaine M. Urbina
Anthony J. Viera
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%