Experimental study on infrared detection of debonding in concrete-filled steel tubular structure under acceleratory period of hydration heat action
Экспериментальное исследование инфракрасного выявления расслоения в сталебетонных трубчатых конструкциях в условиях ускоренного теплового воздействия гидратации
2024-10-30
SCID: 54.1/tjvr347t
Discuss with AI
concrete-filled steel tubular structuresdebonding detectionhydration heatinfrared thermographymultiple linear regression
Figures from the paper
Abstract (AI)
Concrete-filled steel tubular (CFST) Structures often face challenges with debonding during construction, which can markedly compromise the structural integrity. The hydration of concrete can generate significant heat during construction, making the infrared thermography as a potential method for the defect detection. However, effects of concrete hydration behavior, debonding size, and environmental factors on the infrared thermal imaging of CFST debonding remains unclear. This study conducted experiments using four different hydration heating rates and three debonding sizes to simulate debonding detection using infrared imaging during the hydration phase of CFST. The feasibility of the simulation approach was validated through pair-to-pair comparison, and multiple linear regression analysis was employed to evaluate the impact of these factors. The findings highlight that absolute temperature difference has the most significant impact on detection effectiveness regardless of interaction effects. In regression models without interaction, heating rate demonstrated the least impact, Whereas the model considering the interaction showed that the interaction effect of heating rate and debonding size showed a secondary effect. Further examination indicated that interaction effects decrease as heating rate and debonding size decrease.
Key Findings
1
Absolute temperature difference was the most influential factor affecting detection effectiveness, regardless of interaction effects.
2
Experiments varied four hydration heating rates and three debonding sizes to simulate infrared detection during the hydration phase.
3
Pairwise comparisons validated the feasibility of the experimental simulation approach for studying infrared detection of CFST debonding.
4
The study experimentally evaluates infrared thermography for detecting debonding in concrete-filled steel tubular structures during concrete hydration.
5
Without interactions, heating rate had the smallest impact; with interactions included, heating-rate–debonding-size interaction was the secondary factor, decreasing as both variables decreased.
Research Object
Concrete-filled steel tubular (CFST) structures with construction-stage debonding during concrete hydration
Research Subject
Infrared-thermographic detectability of debonding as a function of hydration heating rate, debonding size, and environmental temperature difference
Publication Details
Publication Date
2024-10-30
Journal
Publisher
ISSN
Cited by
13
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest