Quantitative infrared detection methods for debonding in concrete-filled steel tubes during the hydration heat phase

Количественные методы инфракрасного обнаружения отслоений в стальных трубах, заполненных бетоном, на стадии тепловыделения при гидратации
Jianting Zhou, Hong Zhang, Haonan Cai, Chongsheng Cheng
2025-06-16

Otsu’s and K-meansconcrete-filled steel tubesdebonding detectionimage segmentationinfrared thermography
Conducting rapid quantitative debonding detection after the completion of Concrete-filled steel tube (CFST) pouring is crucial for the timely identification and repair of potential structural issues. Currently, there is a lack of an infrared detection method that can perform quantitative detection specifically during the construction phase of CFST. This study proposes a Discreteness-Based Image Preprocessing (DBIP) method, combined with Otsu’s and K-means image segmentation methods, to explore its effectiveness in detecting debonding in CFST during the hydration heat phase. A full-scale CFST model was used to simulate debonding areas of different sizes, and infrared thermal imaging data were collected. The results show that the DBIP method significantly improved detection accuracy, and the DBIP+K-means combination can effectively quantify debonding areas with a minimum side length of 126 mm (10% debonding rate). The study also reveals that the correlation between the F1-score and thermal contrast is linear when the thermal contrast is between 0°C and 0.18°C. When the thermal contrast exceeds 0.18°C, the F1-score stabilizes at approximately 0.8. The finding clarifies the detection accuracy range under different thermal contrast conditions and suggests potential optimization directions for the quantification of CFST debonding in practical application via infrared thermography.
1
A Discreteness-Based Image Preprocessing (DBIP) method was developed and combined with Otsu’s and K-means segmentation for quantitative CFST debonding detection during hydration heat.
2
F1-score increased linearly with thermal contrast from 0°C to 0.18°C, then stabilized at approximately 0.8 above 0.18°C.
3
Full-scale CFST experiments with simulated debonding areas showed that DBIP significantly improves infrared detection accuracy.
4
The DBIP plus K-means approach quantified debonding areas with a minimum side length of 126 mm, corresponding to a 10% debonding rate.
5
The identified relationship between thermal contrast and F1-score defines accuracy ranges and indicates optimization directions for practical infrared thermography of CFST debonding.

concrete-filled steel tubes (CFST) during the hydration heat phase, with simulated debonding areas

quantitative infrared detection and accuracy of debonding areas of different sizes under varying thermal-contrast conditions

Publication Details
Publication Date
2025-06-16
Journal
Publisher
ISSN
Cited by
4
Access Type
Author Information
Authors
Jianting Zhou
Hong Zhang
Haonan Cai
Chongsheng Cheng
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat →
Make a presentation
100%