Assessment of the Fugitive Emission Distributed Sampling (FEDS) system: a mobile, multi-inlet system for continuous emissions monitoring

Оценка системы распределённого отбора проб для выявления выбросов (FEDS): мобильная многовходовая система непрерывного мониторинга выбросов
J.T. Shaw, Neil U. M. Howes, Jessica Connolly, Dragos E. Buculei, Jamie Ryan, Jon Helmore, Nigel Yarrow, David Butterfield, F. Innocenti, Rod A. Robinson
2026-02-16

Fugitive Emission Distributed Sampling (FEDS)WindTraxcontinuous emissions monitoringmethane emissionsreverse dispersion models
Abstract. The National Physical Laboratory (NPL) has developed and trialled a mobile and remotely-operated Fugitive Emission Distributed Sampling (FEDS) system for continuous measurements of emissions at the facility spatial scale. FEDS is capable of both locating and quantifying emission sources over long-term periods and has been deployed at sites around the UK to monitor methane emissions from the natural gas network, landfill, and waste treatment. This work presents validation activities using a controlled release facility (CRF) to test the performance of the measurement system and two reverse dispersion models (Airviro and WindTrax) for emission quantification. Emissions were quantified using prior knowledge of release timings as well as in the absence of this knowledge. High variability in wind direction was shown to negatively impact emission quantification accuracy (especially for Airviro). Emission results were improved by removing periods of high wind variability (low wind persistence) from analysis. Both models performed better when using daily-averaging periods for emissions (Airviro RMSE = 0.37 kg h-1; WindTrax = 0.29 kg h-1) over shorter averaging periods, such as hourly data (Airviro RMSE = 0.77 kg h-1; WindTrax = 2.19 kg h-1). Emission rates were shown to be sensitive to the specified source release height for both models, with discrepancies in model release height relative to the true release height of more than 0.5 m yielding less accurate results. Furthermore, it was shown that emission results were less accurate when using concentration data input from fewer sampling locations, although it would be remiss to recommend a minimum density of sampling locations for a given area based on a single validation study.
1
Controlled-release validation assessed FEDS alongside the Airviro and WindTrax reverse-dispersion models, with and without prior release-timing information.
2
Daily averaging outperformed hourly averaging: Airviro RMSE was 0.37 versus 0.77 kg h−1, while WindTrax RMSE was 0.29 versus 2.19 kg h−1.
3
High wind-direction variability reduced emission-quantification accuracy, particularly for Airviro; excluding low-wind-persistence periods improved results.
4
Quantification accuracy decreased with source-height errors exceeding 0.5 m and with fewer sampling locations; no minimum sampling density is recommended from this single validation study.
5
The mobile, remotely operated FEDS system continuously locates and quantifies facility-scale emissions over long-term monitoring periods.

The mobile, multi-inlet Fugitive Emission Distributed Sampling (FEDS) system and its controlled-release facility measurements of methane emissions

The accuracy and sensitivity of continuous emission-source localization and quantification using FEDS with reverse-dispersion models under varying wind conditions, averaging periods, source release heights, and sampling-location densities

Publication Details
Publication Date
2026-02-16
Journal
Publisher
ISSN
Cited by
0
Access Type
Author Information
Authors
J.T. Shaw
Neil U. M. Howes
Jessica Connolly
Dragos E. Buculei
Jamie Ryan
Jon Helmore
Nigel Yarrow
David Butterfield
F. Innocenti
Rod A. Robinson