Point Sensor Networks Struggle to Detect and Quantify Short Controlled Releases at Oil and Gas Sites
Точечные сенсорные сети с трудом обнаруживают и количественно оценивают кратковременные контролируемые выбросы на объектах нефтегазовой отрасли
2024-04-10
SCID: 54.1/3n7me6rb
Discuss with AI
continuous monitoringcontrolled release testingemission rate estimationoil and gas emissionspoint sensor networks
Figures from the paper
Abstract (AI)
This study evaluated multiple commercially available continuous monitoring (CM) point sensor network (PSN) solutions under single-blind controlled release testing conducted at operational upstream and midstream oil and natural gas (O&G) sites. During releases, PSNs reported site-level emission rate estimates of 0 kg/h between 38 and 86% of the time. When non-zero site-level emission rate estimates were provided, no linear correlation between the release rate and the reported emission rate estimate was observed. The average, aggregated across all PSN solutions during releases, shows 5% of the mixing ratio readings at downwind sensors were greater than the site's baseline plus two standard deviations. Four of seven total PSN solutions tested during this field campaign provided site-level emission rate estimates with the site average relative error ranging from -100% to 24% for solution D, -100% to -43% for solution E, -25% for solution F (solution F was only at one site), and -99% to 430% for solution G, with an overall average of -29% across all sites and solutions. Of all the individual site-level emission rate estimates, only 11% were within ±2.5 kg/h of the study team's best estimate of site-level emissions at the time of the releases.
Key Findings
1
Across four evaluated solutions, site-average relative errors ranged from -100% to 430%, with an overall average error of -29%.
2
Commercial continuous-monitoring point sensor networks frequently reported zero site-level emissions during controlled releases, doing so 38–86% of the time.
3
Only 11% of individual site-level estimates were within ±2.5 kg/h of the study team's best estimate of emissions.
4
Only 5% of downwind sensor mixing-ratio readings exceeded the site baseline by more than two standard deviations during releases.
5
When nonzero estimates were reported, no linear correlation was observed between actual release rates and reported site-level emission estimates.
Research Object
commercially available continuous monitoring point sensor network solutions deployed at operational upstream and midstream oil and natural gas sites
Research Subject
the ability of point sensor networks to detect and quantify short controlled methane releases, including site-level emission-rate estimation accuracy and correlation with release rates
Publication Details
Publication Date
2024-04-10
Journal
Publisher
ISSN
Cited by
31
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest
References available in scid.ai3
Climate Change 2022 – Impacts, Adaptation and Vulnerability2023
A review of close-range and screening technologies for mitigating fugitive methane emissions in upstream oil and gas2019
Robust probabilities of detection and quantification uncertainty for aerial methane detection: Examples for three airborne technologies2023
Cited by5
Comparing Continuous Methane Monitoring Technologies for High-Volume Emissions: A Single-Blind Controlled Release Study2024
Assessing the performance of emerging and existing continuous monitoring solutions under a single-blind controlled testing protocol2025
Design, Build, and Initial Testing of a Portable Methane Measurement Platform2025
A Performance Evaluation Framework for Continuous Methane Monitoring: Effects of Event Association and Metric Choice2026
Assessment of the Fugitive Emission Distributed Sampling (FEDS) system: a mobile, multi-inlet system for continuous emissions monitoring2026