Abstract (AI)
Abstract Here we report a breakthrough in the fabrication of a long lifetime transmon qubit. We use tantalum films as the base superconductor. By using a dry etching process, we obtained transmon qubits with a best T1 lifetime of 503 μs. As a comparison, we also fabricated transmon qubits with other popular materials, including niobium and aluminum, under the same design and fabrication processes. After characterizing their coherence properties, we found that qubits prepared with tantalum films have the best performance. Since the dry etching process is stable and highly anisotropic, it is much more suitable for fabricating complex scalable quantum circuits, when compared to wet etching. As a result, the current breakthrough indicates that the dry etching process of tantalum film is a promising approach to fabricate medium- or large-scale superconducting quantum circuits with a much longer lifetime, meeting the requirements for building practical quantum computers.
Key Findings
1
Dry etching enabled fabrication of tantalum transmons while providing stable, highly anisotropic patterning suitable for complex scalable quantum circuits.
2
Tantalum-based transmon qubits achieved a best measured energy-relaxation lifetime (T1) of 503 μs.
3
The results identify dry-etched tantalum films as a promising route toward medium- and large-scale superconducting circuits with longer qubit lifetimes.
4
Under identical design and fabrication processes, tantalum transmons outperformed comparable niobium- and aluminum-based qubits in coherence properties.
Research Object
Transmon qubits fabricated with tantalum, niobium, and aluminum films
Research Subject
Coherence performance, particularly the T1 lifetime, and the suitability of dry-etched tantalum fabrication for scalable superconducting quantum circuits
Publication Details
Publication Date
2022-01-13
Journal
Publisher
ISSN
Cited by
510
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest
References available in scid.ai3
Cited by4
Cyclically Operated Microwave Single-Photon Counter with Sensitivity of 10−22W/Hz2024
Improving the Lifetime of Aluminum-Based Superconducting Qubits through Atomic Layer Etching and Deposition2025
Systematic improvements in transmon qubit coherence enabled by niobium surface encapsulation2024