Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes

Эффективность терапии с помощью инсулиновой помпы с сенсором глюкозы при сахарном диабете 1-го типа
John B. Buse, William V. Tamborlane, Richard M. Bergenstal, Andrew Ahmann, Bruce A. Perkins, Stephen N. Davis, John Welsh, Steven M. Willi, Tim Peoples, George Dailey, Carol Joyce, Michael A. Wood
2010-06-29

glycated hemoglobin (HbA1c)multiple daily insulin injectionssensor-augmented pump therapysevere hypoglycemia ratetype 1 diabetes
BACKGROUND: Recently developed technologies for the treatment of type 1 diabetes mellitus include a variety of pumps and pumps with glucose sensors. METHODS: In this 1-year, multicenter, randomized, controlled trial, we compared the efficacy of sensor-augmented pump therapy (pump therapy) with that of a regimen of multiple daily insulin injections (injection therapy) in 485 patients (329 adults and 156 children) with inadequately controlled type 1 diabetes. Patients received recombinant insulin analogues and were supervised by expert clinical teams. The primary end point was the change from the baseline glycated hemoglobin level. RESULTS: At 1 year, the baseline mean glycated hemoglobin level (8.3% in the two study groups) had decreased to 7.5% in the pump-therapy group, as compared with 8.1% in the injection-therapy group (P<0.001). The proportion of patients who reached the glycated hemoglobin target (<7%) was greater in the pump-therapy group than in the injection-therapy group. The rate of severe hypoglycemia in the pump-therapy group (13.31 cases per 100 person-years) did not differ significantly from that in the injection-therapy group (13.48 per 100 person-years, P=0.58). There was no significant weight gain in either group. CONCLUSIONS: In both adults and children with inadequately controlled type 1 diabetes, sensor-augmented pump therapy resulted in significant improvement in glycated hemoglobin levels, as compared with injection therapy. A significantly greater proportion of both adults and children in the pump-therapy group than in the injection-therapy group reached the target glycated hemoglobin level. (Funded by Medtronic and others; ClinicalTrials.gov number, NCT00417989.)
1
A significantly greater proportion of adults and children using pump therapy reached the target HbA1c level (<7%) compared with injection therapy.
2
In a 1-year randomized controlled trial of 485 patients, sensor-augmented insulin-pump therapy reduced mean HbA1c from 8.3% to 7.5%, versus 8.1% with multiple daily injections (P<0.001).
3
Rates of severe hypoglycemia did not differ significantly between pump therapy (13.31 cases per 100 person-years) and injection therapy (13.48 per 100 person-years; P=0.58).
4
There was no significant weight gain in either the pump-therapy group or the injection-therapy group over one year.

Sensor-augmented insulin-pump therapy versus multiple daily insulin injections in patients with inadequately controlled type 1 diabetes

Effectiveness measured by change in glycated hemoglobin (HbA1c), proportion achieving target HbA1c (<7%), rates of severe hypoglycemia, and weight change over 1 year

Publication Details
Publication Date
2010-06-29
Journal
Publisher
ISSN
Access Type
Author Information
Authors
John B. Buse
William V. Tamborlane
Richard M. Bergenstal
Andrew Ahmann
Bruce A. Perkins
Stephen N. Davis
John Welsh
Steven M. Willi
Tim Peoples
George Dailey
Carol Joyce
Michael A. Wood
Explore further
Open the scid.ai AI chat with a ready-made request: it will find papers on a similar topic and help build a literature review.
Find similar papers in the chat
Make a presentation
100%