Short- and long-term plasma phenomena in a HiPIMS discharge
Кратковременные и долговременные плазменные явления в разряде HiPIMS
2010-02-22
SCID: 54.1/4cazhdkh
Discuss with AI
HiPIMS dischargeelectron energy distribution functionsremnant plasmasuper-thermal electron populationtime-resolved Langmuir probe
Figures from the paper
Abstract (AI)
Using a time-resolved Langmuir probe the temporal evolution of the bulk plasma parameters in a high-power impulse magnetron sputtering (HiPIMS) discharge was investigated for a number of different discharge conditions. The magnetron was operated in argon between 0.5 and 1.6 Pa with a titanium target and with peak target power densities up to 1000 W cm −2 . The pulse width and repetition rate were held constant at 100 µs and 100 Hz, respectively. Using an OML analysis as well as a Druyvesteyn formulation, the electron densities, effective temperatures and energy distribution functions were obtained throughout the pulse period (0–9 ms), including a detailed study of the first 10 µs, which was achieved with a temporal resolution better than 0.5 µs. In the initial phase of the voltage pulse ( t ∼ 1–4 µs), three distinct groups of electrons (indistinguishable from Maxwellian electrons) were observed, namely 'super-thermal', 'hot' and 'cold' populations with effective temperatures of 70–100 eV, 5–7 eV and 0.8–1 eV, respectively. After 4 µs these groups become energetically indistinguishable from each other to form a single distribution with an electron temperature that decays from about 5 to 3 eV during the rest of the pulse on-time. The presence of the 'super-thermal' electron group pushes the probe floating potential to a very negative value (significantly deeper than −95 V) during the initial period of the pulse. In the off-time, the electron density decays with two-fold characteristic times, revealing initially short-term (30–40 µs) and ultimately long-term (3–4 ms) decay rates. These long decay times lead to a relative high density remnant plasma (2 × 10 9 cm −3 ) at the end of the off-time, which serves to seed the next voltage pulse. The electron temperature and plasma potential also exhibit two-fold decay in the off-time, but with typically somewhat faster decays, particularly for the long-term decay (100–500 µs) up to the end of the off-time. The time evolution of the plasma potential shows that for a considerable fraction of the on-time the plasma potential remains negative (down to −12 V) only becoming positive after t ∼ 60 µs which corresponds to a time of maximum plasma density (typical values of 2 × 10 12 cm −3 ). The generation of super-thermal electrons in the initial phase of the discharge is argued through the development of a simple magnetized-electron bounce model of the expanding sheath.
Key Findings
1
After approximately 4 µs, the electron populations merged into a single distribution whose temperature decreased from about 5 to 3 eV during the remaining pulse on-time.
2
During the initial 1–4 µs, electrons formed super-thermal, hot, and cold populations with effective temperatures of 70–100 eV, 5–7 eV, and 0.8–1 eV, respectively.
3
Off-time electron-density decay had short-term 30–40 µs and long-term 3–4 ms characteristic times, leaving a remnant plasma density of 2 × 10^9 cm−3 that seeds the next pulse.
4
Super-thermal electrons drove the probe floating potential to values significantly more negative than −95 V during the initial pulse phase.
5
Time-resolved Langmuir-probe measurements characterized HiPIMS bulk-plasma evolution over 0–9 ms, including the first 10 µs with better than 0.5 µs resolution.
Research Object
Bulk plasma in a high-power impulse magnetron sputtering (HiPIMS) discharge with an argon plasma and titanium target
Research Subject
Short- and long-term temporal evolution of electron populations, density, temperature, energy distribution, plasma potential, and decay dynamics throughout the pulse and off-time
Publication Details
Publication Date
2010-02-22
Journal
Publisher
ISSN
Cited by
126
Open access PDF
Access Type
Author Information
Download PDF
Subscribe to digest
References available in scid.ai1
Cited by10
Plasma diagnostics for understanding the plasma–surface interaction in HiPIMS discharges: a review2014
The evolution of the plasma potential in a HiPIMS discharge and its relationship to deposition rate2010
Origin of the energetic ions at the substrate generated during high power pulsed magnetron sputtering of titanium2014
On the HiPIMS benefits of multi-pulse operating mode2014
Anomalous cross- B field transport and spokes in HiPIMS plasma2016
Dynamic of the growth flux at the substrate during high-power pulsed magnetron sputtering (HiPIMS) of titanium2013
Time-resolved measurement of film growth during high-power pulsed magnetron sputtering (HIPIMS) of titanium2013
Particle-based simulation of atom and ion transport in HiPIMS: effect of the plasma potential distribution on the ionized flux fraction2023
Electron dynamics in crossed-field discharges2023
Détermination des fonctions de distribution des flux des espèces neutres et ionisées en procédé HiPIMS et corrélations avec les couches minces de type TiN déposées2019